Thermapen® IR — Infrared & Air Probes
Thermapen IR infrared thermometer with air probe - Ideal for HVAC applications
- Patented, automatic 360° rotational display
- Adjustable emissivity for different surfaces
- Motion-sensing sleep mode - probe only
- Free traceable certificate of calibration (probe & IR)
- Polygiene BioMaster product protection
- One-handed operation
- Free protective Pouch included (830-001)
The Thermapen IR Air is two instruments in one compact unit, combining the advanced technology of two ETI designed and manufactured products, the RayTemp 2 Plus infrared thermometer and Thermapen digital air probe thermometer. The fast response air probe is an invaluable tool in establishing the correct air temperature quickly in HVAC, laboratory applications and other temperature sensitive working areas
Housed in a robust ABS case containing Polygiene BioMaster product protection which reduces bacterial growth, the Thermapen IR Air incorporates a motion sensing sleep mode (air probe only) which automatically turns the instrument on/off when set down or picked up, maximising battery life.
Infrared Thermometer
Simply aim the infrared thermometer at the target and press the scan button to display the surface temperature. Please Note: the infrared non-contact function will only measure when the probe is in the closed position.
The Thermapen IR Air thermometer incorporates a max/min temperature function accessed via the mode button (IR only). The distance to target ratio is 5:1, therefore the thermometer should be positioned as close to the target as possible. The default emissivity is 0.95 but can be adjusted between 0.1 and 1.0, if required via the mode button.
Air Probe
The fast response air probe has been designed to be used in HVAC, laboratory applications and other temperature sensitive working areas. The probe conveniently folds back through 180° into the side of the instrument when not in use.
Data sheet
Range - Infrared: | -49.9 to 349.9°C |
---|---|
Range - Probe: | -49.9 to 299.9°C |
Max/Min: | Yes |
Operating Range: | -20 to +50 °C |
Resolution: | 0.1 or 1°C/°F - user selectable |
Accuracy - Infrared: | ±1°C (0 to 100°C) otherwise ±2°C or ±2% of reading whichever is greater |
Accuracy - Probe: | ±0.4°C (-49.9 to 199.9°C) otherwise ± 1°C |
Field of View: | target ratio 5:1 |
Emissivity: | 0.95 default - adjustable 0.1 to 1.00 |
Battery: | 2 x 3 volt CR2032 lithium coin cell |
Battery Life: | 1000 hours continuous use |
Display: | 12mm (horizontal) & 10mm (vertical) LCD - 360° rotation |
Dimensions: | 19 x 50 x 157mm |
Weight: | 125 grams |
Case Material: | ABS plastic includes Biomaster product protection |
Certification: | FREE traceable calibration certificate |