Thermapen IR infrared thermometer with foldaway probe

Enables users to take accurate surface and internal temperatures using one compact device.

It combines two of ETI's most popular products: the RayTemp 2 Infrared thermometer 
and the Thermapen thermometer

  • Infrared and penetration probe thermometer
  • Measures surface and internal temperatures
  • Adjustable emissivity for different surfaces
  • 360° auto-rotating display
  • Motion-sensing sleep mode
  • Biomaster product protection
  • Free traceable certificate of calibration
  • UK Patent No. GB 2504936
ColourRed
Product code:
228-045

Quickly and easily switch between surface and internal temperature measurements with the Thermapen IR. Featuring a compact design for easy transportation, this infrared thermometer is designed to make temperature checks simple. The display automatically rotates 360°, making it easy to read from any angle and in either hand.

The Thermapen infrared thermometer casing includes Polygiene BioMaster product protection to reduce bacterial growth.

Product Information

Product specifications
Accuracy ±0.4°C
Additional Ranges -49.9 to 299.9 °C [Probe]
Alarm Volume N/A
App Used N/A
Auto Off
Battery CR2032
Battery Life 1,000 hours
Battery Quantity 2
Battery Weight 2.4
Biomaster
Bluetooth Module N/A
C/F Switchable
Cable Temperature Range N/A
Calibration Included Traceable
Case Material PC/ABS Plastic
Emissivity 0.95 default - adjustable 0.1 to 1.00
Guarantee 2 years
Handle Type N/A
Hold
IP Rating N/A
Lead Length N/A
Lead Material N/A
Lead Style N/A
Low Battery Indication
Made in the UK
Max/Min
Memory N/A
Operating Range -20ºC to 50°C
Packaged Weight (g) 158.5
Probe Response Time 3 seconds
Probe Style Penetration/IR
Product Dimensions 157 x 50 x 19mm
Product Weight 117.5
Range -49.9 to 349.9 °C [IR]
Reese's Law Battery Warning
Resolution 0.1
Rotating Display
Sample Rate N/A
Sensor Type Type K/IR
Software N/A
Trim Amount N/A
USB Cable Code N/A
USB Cable Type N/A

Frequently Asked Questions

What is the Thermapen® IR used for?

The Thermapen® IR combines a non-contact infrared thermometer and penetration probe in one instrument, allowing you to measure both surface and internal temperatures. It is ideal for commercial kitchens, catering and food production where quick, reliable temperature checks are essential.



What is the difference between infrared and probe temperature measurement?

The infrared sensor measures the surface temperature of an object without making contact, while the penetration probe measures the internal temperature of food. Infrared is useful for quick surface checks, but a penetration probe should be used when an internal food temperature is required for food safety.

Is the Thermapen® IR suitable for HACCP and food safety checks?

Yes. The Thermapen® IR is suitable for professional temperature monitoring as part of HACCP and food safety procedures. The infrared function enables quick surface temperature checks, while the penetration probe can be used to check the internal temperature of cooked, chilled and reheated foods.

How accurate is the Thermapen® IR?

The penetration probe is accurate to ±0.4 °C between -49.9 and 199.9 °C, and ±1 °C outside this range. The infrared sensor is accurate to ±1 °C between 0 and 100 °C, and ±2 °C or ±2% of the reading outside this range, whichever is greater.

How quickly does the Thermapen® IR measure temperature?

The penetration probe provides internal temperature readings in just three seconds, making it suitable for quick, routine temperature checks in busy commercial food environments. The infrared function provides rapid, non-contact surface temperature measurements.

How close should the Thermapen® IR be to the surface being measured?

The Thermapen® IR has a 5:1 distance-to-target ratio, meaning the area being measured becomes larger as you move further away from the target. For the most accurate infrared readings, position the thermometer as close to the surface as practical.

What is emissivity on the Thermapen® IR?

Different surfaces can give different infrared readings depending on their material and finish. The emissivity setting helps the Thermapen® IR account for these differences to improve measurement accuracy. It is set to 0.95 by default and can be adjusted between 0.1 and 1.0 for different surfaces.

Does the Thermapen® IR come with a calibration certificate?

Yes. The Thermapen® IR is supplied with a free traceable calibration certificate, providing documented confirmation of its accuracy. Additional calibration options are available for businesses with specific quality or compliance requirements.