Premium Bluetooth Legionella Thermometer Kit

Premium Bluetooth Legionella Thermometer Kit

£279.00
£334.80 inc. VAT
Regular price £0.00 Sale price £279.00
Sale price inc. VAT £334.80 inc. VAT
Skip to product information
Premium Bluetooth Legionella Thermometer Kit

Premium Bluetooth Legionella Thermometer Kit

£279.00
£334.80 inc. VAT
Regular price £0.00 Sale price £279.00
Sale price inc. VAT £334.80 inc. VAT

Premium Bluetooth® enabled water thermometer kit

  • Paperless legionella risk assessments
  • Free software, no ongoing costs
  • SDK and technical support available
  • Thermocouple type K thermometer
  • Penetration, surface and wire probes
  • Timer and wipes
  • Free carrying case included

Take accurate, time-stamped temperatures for Legionella risk assessments with this premium Bluetooth-enabled thermometer kit. Three probes included for measuring taps, pipes and tanks.

Product code:
860-847

The Legionnaires' Premium Water Temperature Thermometer Kit contains everything required to monitor water supply temperatures to prevent legionella growth.

Each Legionnaires' Premium Water Temperature Thermometer Kit contains the following:

Product Information

Product specifications
Battery 3 x 1.5 volt AAA
Battery Life minimum 5 years (10000 hours)
Case Material ABS plastic includes Biomaster product protection
Guarantee two years
Max/Min
Product Dimensions 25 x 56 x 128mm
Product Weight 130 grams
Resolution 0.1 °C & 1 °C
Sensor Type K- Thermocouple
Instructions
Legionnaires' Premium Water Temperature Thermometer Kit

Therma 1 legionella thermometer

The legionnaires' test kit includes a robust, easy-to-use Therma water temperature thermometer. Featuring a wide temperature range of -100 to 1370 °C, the Therma 1 legionnaires' thermometer is compatible with any of our type K thermocouple probes. 

The Therma 1 has a minimum of five years of battery life and features an auto power-off function to reduce battery usage. In addition, the hold function makes recording temperatures easy.

Waterproof Legionella Thermometer Kit

Complete legionella testing kit

The premium legionnaires' test kit features three different probes for testing various water system elements. The Penetration Temperature Probe can be used to record tap water temperatures, the Ribbon Surface Temperature Probe for pipe surfaces and tanks and the Wire Probe is ideal for hard-to-reach areas.

Legionnaires' Premium Water Temperature Thermometer Kit

The kit also comes with a FREE Water-Resistant Countdown Timer to ensure tests are conducted for the correct amount of time. The mini tub of Probe Wipes makes probes easy to wipe clean. The legionella testing kit comes safely stored inside an ABS carrying case, making it easy to transport everything you need to different water outlets.

A FREE traceable calibration certificate is also included so that you can be confident in the accuracy of your tests.

Frequently Asked Questions

How to test for legionella risks in water?

Incorrect water temperature is a key risk factor for Legionella growth. The Legionella bacteria multiply in water at temperatures between 20 to 45 °C, particularly if a supply of nutrients is present, such as scale, rust, sludge or algae.

A typical method of control is to store cold water below 20 °C. Hot water should be stored above 60 °C and distributed at above 50 °C. Regular testing using a water temperature thermometer helps control legionella risks.

Who needs to check water temperatures for legionella risks?

Current legislation means that you must organise a risk assessment if you are an employer or person in control of premises. The revised Approved Code of Practice (ACOP) issued by the Government's Health and Safety Executive (HSE) significantly extends the scope of its guidance on controlling legionella bacteria in water.

The code now applies to all workplace hot and cold water systems regardless of their capacity; the lower limit of 300 litres previously used to exclude domestic systems no longer applies. Whilst domestic systems may represent a risk, the code only applies to risk arising from work activity.

This means all employers managing premises with hot/cold water systems or wet cooling systems are legally responsible for identifying contamination risks and preventing or controlling them.

What is included in the Premium Bluetooth Legionella Kit?

This kit gives you smart technology alongside all the professional tools needed for water safety testing. Packed inside a hard carrying case, you get the Therma K Blue thermometer, three specific temperature probes, a countdown timer, and 100 anti-bacterial probe wipes. We also include a free traceable calibration certificate for your compiance records.

How does the Bluetooth thermometer make Legionella testing easier?

The Standard Bluetooth Legionella Thermometer Kit allows you to complete paperless risk assessments. Using Bluetooth, the Therma K Blue thermometer sends accurate temperature readings directly to your smartphone or tablet with a single tap. This eliminates the need for manual paperwork, reduces human error, and creates an instant, time-stamped digital log for your health and safety records.

Do I have to pay a monthly fee for the thermometer software?

No, there are no ongoing costs or subscription fees. The kit pairs with the free ThermaData Hub software and mobile app. Through the app, you can build custom checklists for your building, monitor your temperature results, and export the data easily. For larger businesses, a free SDK (Software Development Kit) is also available to integrate the thermometer with your own existing systems.

How regularly do I need to check my water temperatures?

The Health and Safety Executive (HSE) says you must check your water often to follow the rules. Usually, you should test your hot and cold taps once a month. Hot water needs to reach 50 °C within one minute of turning on the tap. Cold water must drop below 20 °C within two minutes. Places with vulnerable people, like hospitals or care homes, must do daily checks on their main water outlets.

Who is legally responsible for Legionella temperature monitoring?

The Approved Code of Practice (ACoP L8) applies to all workplace hot and cold water systems, regardless of their capacity. Any employer, landlord, or facility manager overseeing premises with hot or cold water systems is legally responsible for identifying contamination risks and implementing a reliable temperature monitoring programme to control them.

You may also like